uvq series, Elektronika, Zasilacze i przetwornice AC-DC DC-DC noty katalogowe EDW, Noty zasilacze, Murata Power ...
[ Pobierz całość w formacie PDF ] UVQ Series Low Proile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters ORDERING GUIDE SUMMARY Model V o u t Range I o u t Range V i n Range Eficiency All Models 1.2V to 48V 2.5A to 40A 18-36V or 36-75V Up to 92.%, model dependent INPUT CHARACTERISTICS Parameter Typ. @ 25°C, full load Notes Voltage Range 18-36 or 36-75 Volts 24V or 48V nominal Current, full power Up to 5.6 Amps Model dependent Isolation 2kVdc to 2250V Model dependent Typical unit Remote On/Off Control Switch or FET control Positive or negative logic FEATURES ■ Standard quarter-brick package/pinout ■ Outputs from 1.5 to 48V up to 125W ■ Low proile 0.42" height ■ 24 and 48Vdc nominal inputs ■ Fully isolated, 2250Vdc (BASIC) insulation ■ Designed for RoHS compliance ■ Output overvoltage/short-circuit protected ■ On/Off control, trim and sense functions ■ High eficiency to 92% ■ Protected against temp. and voltage limits ■ UL/IEC/EN60950-1 safety approvals ■ Qual/HALT/EMI tested OUTPUT CHARACTERISTICS Parameter Typ. @ 25°C, full load Notes Voltage 1.5 to 48 Volts ±10% Trimmable Current 2.5 to 40 Amps fullscale No minimum load Accuracy Down to 1% of V NOM Most models Ripple & Noise (to 20MHz) Down to 35mVp-p Model dependent Line and Load Regulation Down to ±0.125%/±0.25% Model dependent Overcurrent Protection 150% of I OUT max. With hiccup auto-restart Overtemperature Protection +125 °C Eficiency (minimum) See Performance Speciications GENERAL SPECIFICATIONS Parameter Typ. @ 25°C, full load Notes Dynamic Load Response Down to 50μsec Model dependent Operating Temperature Range –40 to +110°C With baseplate, see derating curve Safety UL/IEC/EN 60950-1 and CSA C22.2-No.234 MECHANICAL CHARACTER ISTICS With baseplate 1.45 x 2.30 x 0.5 inches (36.83 x 58.42 x 12.7 mm) Without baseplate 1.45 x 2.30 x 0.42 inches (36.83 x 58.42 x 10.67 mm) See Performance Speciications, page 2 PRODUCT OVERVIEW For eficient, fully isolated DC power in the small- est space, Murata Power Solutions' UVQ series quarter bricks offer output voltages from 1.5 to 48 Volts with currents up to 40 Amps. UVQs operate over a wide temperature range (up to +70°C at 200 lfm airlow) at full-rated power. The optional mounting baseplate extends this to all practical temperature ranges at full power. UVQ’s achieve these impressive speciications while delivering excellent electrical performance. Overall noise is 35mVp-p (3.3V models) with fast step response (down to 50µsec). These converters offer high stability even with no load and tight out- put regulation. The unit is fully protected against input over and undervoltage, output overcur- rent and short circuit. An on-board temperature sensor shuts down the converter if thermal limits are reached. Protection uses the “hiccup” (auto restart) method. A convenient remote On/Off control input oper- ates by external digital logic, relay or transistor input. To compensate for longer wiring and to retain output voltage accuracy at the load, UVQ’s include a Sense input to dynamically correct for ohmic losses. A trim input may be connected to a user’s adjustment potentiometer or trim resistors for output voltage calibration closer than the standard accuracy. UVQ’s include industry-standard safety certi- ications and BASIC I/O insulation provides 2250 Volt input/output isolation. Radiation emission testing is performed to widely-accepted EMC standards. Contact MPS for details on HALT quali- ication testing. The UVQ’s may be considered as higher performance replacements for some MPS USQ models. Pb Ḥ For full details go to www.murata-ps.com/rohs Lead-free construction/attach www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UVQ Models.B04 Page 1 of 25 UVQ Series Low Proile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance Speciications and Ordering Guide ➀ ORDERING GUIDE Output Input Package (Case, Pinout) R/N (mVp-p) ➁ Regulation (Max.) ➂ Eficiency) V o u t (Volts) I o u t (Amps) Power (Watts) V i n Nom. (Volts) Range (Volts) I i n , No Load (mA) I i n , Full Load (Amps) Root Models Typ. Max. Line Load Min. Typ. UVQ-1.2/40-D48 1.2 40 48 TBD TBD TBD TBD 48 36-75 TBD TBD TBD TBD C59, P32 UVQ-1.5/40-D24 1.5 40 60 30 60 ±0.075% ±0.05% 24 18-36 80 2.84 86.5% 88% C59, P32 UVQ-1.5/40-D48 1.5 40 60 TBD TBD TBD TBD 48 36-75 TBD TBD TBD TBD C59, P32 UVQ-1.8/40-D48 1.8 40 72 TBD TBD TBD TBD 48 36-75 TBD TBD TBD TBD C59, P32 UVQ-2.5/35-D24 60 ±0.05% ±0.05% 24 18-36 100 4.14 86% 88% 2.5 35 87.5 UVQ-2.5/40-D48 60 ±0.05% ±0.05% 48 36-75 100 2.37 87% 88% 35 UVQ-3.3/30-D24 65 ±0.1% ±0.25% 24 18-36 180 4.58 88.5% 90% 3.3 30 99 UVQ-3.3/35-D48 40 ±0.05% ±0.25% 48 36-75 130 2.7 87% 89% UVQ-5/20-D24 30 50 ±0.05% ±0.05% 24 18-36 180 4.53 91% 92% 5 20 100 UVQ-5/20-D48 20 25 ±0.05% ±0.05% 48 36-75 80 2.31 88.5% 90% UVQ-12/8-D24 8 96 95 130 ±0.1% ±0.1% 24 18-36 90 4.4 89% 91% 12 UVQ-12/10-D48 10 120 110 160 ±0.75% ±0.05% 48 36-75 60 2.78 88.5% 90% C59, P32 UVQ-15/7-D24 85 150 ±0.05% ±0.05% 24 18-36 103 4.85 88.5% 90.3% 15 7 105 UVQ-15/7-D48 120 150 ±0.05% ±0.02% 48 36-75 60 2.39 90% 91.5% UVQ-18/5.6-D24 5.6 100.8 125 185 ±0.05% ±0.075% 24 18-36 140 4.69 88% 89.5% 18 UVQ-18/6-D48 6 125 185 ±0.05% ±0.075% 48 36-75 80 2.5 88.3% 90% UVQ-24/4.5-D24 108 60 100 ±0.075% ±0.15% 24 18-36 45 5.03 88% 89.5% 24 4.5 UVQ-24/4.5-D48 75 130 ±0.075% ±0.25% 48 36-75 45 2.49 89% 90.5% UVQ-48/2.5-D24 100 200 ±0.1% ±0.2% 24 18-36 45 4.4 89% 91% 48 2.5 120 UVQ-48/2.5-D48 250 375 ±0.175% ±0.2% 48 36-75 30 2.71 91% 92.3% These are partial model numbers. Please refer to the full model number struc- ture for complete ordering part numbers. Output capacitors are 1uF ceramic || 10 uF electrolytic. Input cap is 22 uF, low ESR, except UVQ-24/4.5 is 33uF and UVQ-48/2.5 uses no input cap. I/O caps are necessary for our test equipment and may not be needed for your application. o u t = 14 Amps max. with V i n = 18-19.5 Volts. Min. I o u t = 3 Amps. All speciications are at nominal line voltage and full load, +25°C unless other- wise noted. See detailed speciications. UVQ Pin 9 Baseplate Connection The UVQ series may include an optional installed baseplate for extended thermal management. Various UVQ models (see list below) are also available with an additional pin 9 on special order which connects to the baseplate but is electrically isolated from the rest of the converter. Please refer to the mechani- cal drawings. Models available with Pin 9: UVQ-12/10-D48 UVQ-1.5/40-D24 Models which are NOT available with Pin 9: UVQ-5/20-D24 and –D48 Pin 9 offers a positive method of controlling the electrical potential of the baseplate, independent of the converter. Some baseplate models cannot include pin 9 and in such cases, the baseplate is grounded by the mounting bolts. Or consider adding an external lugged washer with a grounding terminal. UVQ-3.3/30-D24 UVQ-3.3/35-D48 UVQ-2.5/35-D24 UVQ-2.5/40-D48 The baseplate may be ordered by adding a “B” to the model number tree and pin 9 will be pre-installed by adding a “9”. The two options are separate. Please refer to the Ordering Guide. Do not order pin 9 without the baseplate. Note that “pin 9” converters may be on limited forecast, requiring minimum order quantities and scheduled deliveries. Other models which are not listed will be reviewed for future pin 9 accomo- dation. www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UVQ Models.B04 Page 2 of 25 UVQ Series Low Proile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters PART NUMBER STRUCTURE - B 9 LX - C U VQ 3.3 20 D48 N / - RoHS-6 compliant * Output Coniguration U = Unipolar/Single Alternate Pin Length: L1 = 0.110 (2.79mm) L2 = 0.145 (3.68mm) Quarter-Brick Package Blank = Standard pin length Nominal Output Voltage Baseplate Pin 9, see Mechanical Drawings: (special order) 1.2 to 48 Volts 9 = Pin 9 installed (see description on pg. 2) Blank = No pin 9 Maximum Rated Output Current in Amps B = Baseplate installed Blank = No baseplate Input Voltage Range: * Note: Not all model number combinations are available. Contact Murata Power Solutions. (DATEL). D24 = 18-36 Volts (24V nominal) Remote On/Off Control Polarity: D48 = 36-75 Volts (48V nominal) Add "P" for positive polarity Add "N" for negative polarity +SENSE (7) +V IN (3) +V OUT (8) Baseplate (9) Optional SWITCH CONTROL –V OUT (4) –V IN (1) –SENSE (5) PWM CONTROLLER OPTO ISOLATION REFERENCE & ERROR AMP V OUT TRIM (6) INPUT UNDERVOLTAGE, INPUT OVERVOLTAGE, AND OUTPUT OVERVOLTAGE COMPARATORS * Can be ordered with positive (standard) or negative (optional) polarity. REMOTE ON/OFF CONTROL* (2) Typical coniguration — some models use a different topology Figure 1. Simpliied Schematic www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UVQ Models.B04 Page 3 of 25 UVQ Series Low Proile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Speciications 24V Models Typical @ T a = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Input Input voltage range See ordering guide Start-up threshold, (V) min. 17 17 17 17 17 17 17 17 17 Undervoltage shutdown, (V) 14 16 16.25 16 16.25 16 16 Overvoltage shutdown (V) none 39 none Relected (back) ripple current 2 10-50 mA pk-pk, model dependent Input Current Full load conditions See ordering guide. Inrush transient, (A 2 sec) 0.5 0.5 0.05 0.5 0.1 1 1 0.05 0.05 Output short circuit, (mA) 40 50 10 320 50 50 50 No load, mA 80 100 180 160 90 103 140 45 30 Low line (V i n = min.), (Amps) 3.79 5.49 6.04 5.57 5.93 6.52 6.29 6.67 3.60 Standby mode, (Off, UV, OT shutdown) 1-4mA, model dependent Internal input ilter type L-C Pi-type L-C Reverse polarity protection See notes. Remote On/Off Control 5 Positive logic, "P" sufix (speciications are max) OFF = Ground pin to +0.8V ON = Open or +5V to +V i n max. Negative logic, "N" sufix (speciications are max) OFF = Open or +5V to +V i n max ON = Ground pin to+0.8V max Current 1-8 mA, model dependent www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UVQ Models.B04 Page 4 of 25 UVQ Series Low Proile, Isolated Quarter Brick 2.5–40 Amp DC/DC Converters Performance/Functional Speciications 24V Models Typical @ T a = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1) Output Voltage output range See ordering guide. Voltage output accuracy (50% load) ±1.5% of V n o m ±1.25% of V n o m ±1% of V n o m Adjustment range –20 to +10% of V n o m . ±10% of V n o m . Temperature coeficient ±0.02% of V o u t range per °C Minimum loading No minimum load 3 amps No minimum load Remote sense compensation +10%. Ripple/noise See ordering guide. Line/Load regulation See ordering guide. Eficiency See ordering guide. Maximum capacitive loading, Low ESR <0.02Ω max., resistive load, (μF) 10,000 5000 4700 2200 Current limit inception (98% of V o u t , after warmup), (Amps) 45 44 36 24 10 9.5 7 5.8 3.4 Short circuit protection method Current limiting, hiccup autorestart. Remove overload for recovery. Short circuit current, (Amps) 3.6 3 3 3 1.5 15 mA 3 5 2.8 Short circuit duration Output may be shorted continuously to ground (no damage). Overvoltage protection, (via magnetic feedback) 14.4 Volts max 2.3 Volts 3 Volts max 6.8 Volts max 3.96 Volts max 22 Volts max 29 Volts max 59 Volts max Isolation Characteristics Isolation Voltage Input to Output, (Volts min) 2000 Input to baseplate 1500 Baseplate to output, (Volts min) 1500 1000 1500 Isolation resistance 100 MΩ Isolation capacitance, (pF) 1500 1000 2000 50 Isolation safety rating Basic insulation www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UVQ Models.B04 Page 5 of 25
[ Pobierz całość w formacie PDF ]
zanotowane.pldoc.pisz.plpdf.pisz.planette.xlx.pl
|
|
|
Tematy
Startupdate-eagle-40, Programy (Programs), Elektronika, Eagle, Dodatki, Docuniwersalny wzmacniacz 100W, SCHEMATY ELEKTRONIKA, █ WzmacniaczeUrządzenia elektryczne - zagrożenia, Analiza i ocena zagrożeń(1)Urządzenia i instalacje elektryczne na placu budowy, bhp zachomikowane, BHPustawa o informatyzacji, Administracja II st. e-administracja, Elektroniczne zarządzanie dokumentamiUrzdzenia i instalacje elektryczne na budowie, bhp zachomikowane, seerox Instrukcje BHPuwagi coolfona do zad5 z egz, Notatki, Elektronika AGH III rok, Pendriveurządzenia elektr. diagnoza, GOLF-1998 BORA-1999 Instrukcja Naprawuniwersalny algorytm, Ratownictwo Medyczne UMED - I rok, elektrokardiologia - fakultetUrzae 133 dzenia techniki komputerowej cz.II, Elektronika, informatyka
zanotowane.pldoc.pisz.plpdf.pisz.plswpc.opx.pl
|